Defrost, Temp control – Hill Phoenix OSAA User Manual

Page 22

Advertising
background image

18

DEFROST

AND

TEMP CONTROL

• Electric defrost termination control sensor bulb location
• Electric defrost termination probe location
• Temperature control sensor bulb location (OSA)

It is important to consult the control

setting guidelines shown on page 17 before
setting defrost times. Further adjustment may
be required depending on store conditions.

These cases are equipped with Electric

Defrost. The sensor bulb and probe for electric
defrost termination and the sensor bulb for
temperature control are located behind the
front baffle at the location shown in diagram 1
below.

The defrost termination control thermo-

stat and the temperature control thermostat
are located under the rear sill behind an easily
removable cover, as shown in diagram 2.

1

Thermostat
Location

Rear Sill

2

Ballast
Cover

Advertising