Termination locations, Warning, A. flue termination minimum clearances – Heat & Glo Fireplace VRTIKL-AU User Manual

Page 7

Advertising
background image

7

Heat & Glo • VRTIKL-AU • 2123-900 • 7/07

Figure 3.2 Multiple Vertical Termination

Figure 3.3 specifi es minimum fl ue heights for various
pitched roofs.

Figure 3.3 Minimum Height from Roof to Lowest Discharge
Opening

610 mm

610 mm

HORIZONTAL

OVERHANG

VERTICAL

WALL

TERMINATION

CAP

LOWEST

DISCHARGE

OPENING

H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING

Angle

H (Min.) M

0°-26.6° ........................................................ 0.30*
26.6°-30.3° ........................................................ 0.38*
30.3°-33.7° ........................................................ 0.46*
33.7°-36.9° ........................................................ 0.61*
36.9°-39.8° ........................................................ 0.76
39.8°-42.5° ........................................................ 0.99
42.5°-45.0° ........................................................ 1.22
45.0°-49.4° ........................................................ 1.52
49.4°-53.1° ........................................................ 1.83
53.1°-56.3° ........................................................ 2.13
56.3°-59.0° ........................................................ 2.29
59.0°-60.3° ........................................................ 2.44

*.91 M minimum in snow regions

Gas Termination Wood & Fuel Oil Termination

A

150 mm

510 mm

610 mm

460 mm

GAS

TERMINATION

GAS, WOOD OR FUEL

OIL TERMINATION

A

(MINIMUM) TO

PERPENDICULAR

WALL

(GAS ONLY)

A. Flue Termination Minimum Clearances

Fire Risk.

Explosion Risk.

Maintain fl ue clearance to combustibles as
specifi ed.

• Do not pack air space with insulation or other

materials.

Failure to keep insulation or other materials
away from fl ue pipe may cause fi re.

Figure 3.1

3

3

Termination Locations

Measure horizontal clearances from this surface.

Measure vertical clearances from this surface.

(See Figure 3.4 for specifi c clearances)

WARNING