Heath Zenith 175 WATT MERCURY VAPOR DUSK TO DAWN SECURITY LIGHT SL-5653 User Manual

Installation instructions with two piece arm

Advertising
background image

Model SL-5653

175 Watt Mercury Vapor Dusk to Dawn Security Light

© 2003 DESA Specialty Products™

598-1062-02

Installation Instructions With Two Piece Arm

READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.

NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through

conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of
the system.

Lens/Reflector

Assembly

Mounting

Arm

Lag

Screw

(4)

Flat Washer (10)

Mounting

Bracket

Photocontrol

Ground

Screw

CAUTION: Make sure the power is off before starting

the installation.

1. Select a location on a flat wall with structurally sound wood

and from 10 to 25 feet from the ground. The wood should
be at least one inch thick to safely secure the fixture.

2. Slide the curved section of the mounting arm into the

mounting bracket. Tighten the bolts on the mounting
bracket evenly.

3. Using the mounting arm and bracket as a guide mark

four mounting holes. We suggest drilling 3/16" pilot holes
for the lag screws.

4. Mount the arm and bracket using four lag screws and

washers provided.

5. Place a ring of silicone caulk around mounting arm (see

illustration). Slide the straight section of the mounting arm
on to the curved section aligning the predrilled holes.

6. Secure the two sections with two bolts, nuts and four

washers provided. Place silicone caulk on top of the bolts
and washers to prevent water from entering.

7. Thread your outdoor cable or flexible conduit through the

mounting arm.

8. Loosely connect the mounting strap to the fixture using

two bolts provided.

9. Slide the fixture on to the mounting arm until the fixture

comes to a stop. Secure the fixture to the mounting arm
by tightening the two mounting strap bolts.

10.Connect the fixture wires to the service wires using the wire

nuts provided (black to black and white to white). Push
the connections as far as possible into the straight arm.

11. This fixture must be grounded. Connect the service

ground under the head of the green ground screw and
secure to the mounting strap.

12.Install the lens/reflector assembly with two screws and

washers provided.

13.Install ONLY a 175 watt mercury vapor type H39

lamp (provided).

14.Loosen the screw in the center of the photocontrol socket

two turns. Twist the socket so that the arrow points north.
Note: There is a stop to prevent the socket from turning
all the way around. If you have trouble turning the socket,
try turning it the other direction. Retighten the screw in
the center of the socket.

Mounting Strap

Silicone

Caulk

15.Align the photocontrol (it will only plug-in one way). Plug

it in and twist clockwise until it stops.

To test operation during daylight, cover the photocontrol with
a small box. Turn on the power. Not all photocontrols are
alike. Some may have a time delay of a few minutes, others
will turn on as soon as power is applied. The light will take up
to ten minutes to reach full brightness. Uncover the
photocontrol and your unit will operate automatically—on at
dusk, off at dawn.