Examples, 54 set config zoning parameters – HP 2/8q Fibre Channel User Manual

Page 141

Advertising
background image

Command Line Interface

141

HP StorageWorks 2/8q Fibre Channel Switch Management User Guide

ZONING

Initiates an editing session in which to change switch zoning attributes. The system
displays each parameter one line at a time and prompts you for a value. For each
parameter, enter a new value or press Enter to accept the current value shown in
brackets.

Examples

The following is an example of the

SET CONFIG PORT

command:

2/8q FC Switch #> admin start

2/8q FC Switch (admin) #> config edit

2/8q FC Switch (admin-config) #> set config port 1

A list of attributes with formatting and current values will follow.

Enter a new value or simply press the ENTER key to accept the current
value.

If you wish to terminate this process before reaching the end of the
list

press 'q' or 'Q' and the ENTER key to do so.

Configuring Port Number: 1

------------------------

AdminState (1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online]

LinkSpeed (1=1Gb/s, 2=2Gb/s, 3=Auto) [Auto ]

PortType (GL / G / F / FL / Donor) [GL ]

SymPortName (string, max=32 chars) [Port1 ]

ALFairness (True / False) [False ]

DeviceScanEnable (True / False) [True ]

ForceOfflineRSCN (True / False) [False ]

ARB_FF (True / False) [False ]

InteropCredit (decimal value, 0-255) [0 ]

Table 54: Set config zoning parameters

Parameter

Description

InteropAutoSave

Available only when the InteropMode parameter is True, this

parameter enables (True) or disables (False) the saving of

changes to active zone set in the switch’s permanent memory.

See “

Set config threshold parameters

” on page 140. The

default is True. (not supported)
Disabling the Autosave parameter can be useful to prevent

the propagation of zoning information when experimenting

with different zoning schemes. However, leaving the Autosave

parameter disabled can disrupt device configurations should

a switch have to be reset. For this reason, the Autosave

parameter should be enabled in a production environment.

Default Visibility

Enables (All) or disables (None) communication among the

switch’s ports/devices and the fabric in the absence of an

active zone set. The default is All.

Advertising