Locking beacon ii smart controller error codes, Locking beacon ii smart controller & error codes – Heatcraft Refrigeration Products BEACON II SMART CONTROLLER H-IM-80C User Manual

Page 10

Advertising
background image

10

EXVSET

- Expansion valve step setting (Stepper Motor setting 0 to 255 steps: use

+ button to check other evaporators if Master/slave)

SUCTMP

Evaporator Suction temperature (Measured by the Suction Sensor)

SSVTMP

Saturated Suction temperature at the Evaporator (Determined by Suction

Transducer)

SUCPRE

Evaporator Suction Pressure (Measured by Suction Transducer)

OD TMP

Actual outdoor ambient temperature (Measured at the Condensing

Unit)

DEFTMP

Evaporator coil temperature (Used to terminate defrost)

DEFTIM

- Defrost Time: Length of last defrost

CMPCYC

- Comp Cycles: No of Compressor Cycles since 12:00 midnight

CMPRUN

- Comp run time (Measured since 12:00 midnight)

SPRTMP

Spare sensor temperature input

VERSON

– Software Version: For each controller (use “+” button to check other

evaporators, if Master/slave)

VERSON

- Software Version: for Beacon II Smart Controller

When multiple evaporators are connected as master/slave depressing the + or - button
will display information specific to each evaporator. Units in a master/slave connection
are numbered 1 through 4.
The first evaporator connected to the BEACON II SMART CONTROLLER

MULTI-

OUT

Terminals is Evaporator # 1.

LOCKING BEACON II SMART CONTROLLER

BEACON II SMART CONTROLLER is lockable to prevent programmed settings changes
by unauthorized personnel. When the Controller is Locked, all the Buttons, except for the
Monitor and Prog Review Buttons, are disabled.

To LOCK the settings, do the following:

• Press “PROG REVIEW” button.
• Press and hold “MONITOR” button
• While holding “MONITOR” button, Press “ENTER” button.
• The LCD will display LOCK

This will prevent unauthorized persons from changing any settings for system displayed.
To UNLOCK the Controller, repeat these steps. LCD will display “UNLOCK.” Note: Each
system must be locked or unlocked separately.

ERROR CODES

*BXSEN -

Room temperature sensor shorted, open or not installed

*DFSEN -

Defrost temperature sensor shorted, open or not installed

*STSEN -

Suction Temperature sensor shorted, open or not installed

Locking Beacon II Smart Controller & Error Codes