Installation, Log set installation, Important – Hampton Direct U32 User Manual

Page 10

Advertising
background image

10

U32-5 FPI Direct Vent Gas Insert

LOG SET INSTALLATION

Log kit (Part # 425-930) contains the following pieces:

a) 27-31

Rear

Log

b)

27-32

Middle Left Log

c) 27-33

Front

Log

d) 27-34

Middle

Right

Log

e) 27-35

Left

Log

f) 27-36

Right

Log

g) 902-154

Embers

Lava

h) 902-179

Vermiculite

i) 902-153 Rock

Wool

j) 946-669 Platinum

Embers

(supplied with packaged manual)

27-34

27-33

27-31

27-36

1) Carefully remove the logs from the box and unwrap them. The logs

are fragile, handle with care - do not force into position.

3) Fit log 27-31 into the pins on the rear log tray.

4) Fit log 27-32 into the pins on the middle left hand side of the

burner.

27-32

27-32

27-35

Vermiculite and Embers

27-31

Read the instructions below carefully and refer to the images.
Dangerous operating conditions may occur if the logs are not
positioned in their correct locations. If the logs are broken
do not use the unit until they are replaced. Broken logs can
interfere with the pilot operation.

IMPORTANT

For LP units the Air Defl ector MUST be installed prior

to log installation. See "Conversion from NG to LP"

section in manual for installation instructions.

2) Spread vermiculite around the exposed fi rebox base. Then take some

embers and spread them over the vermiculite as shown.

INSTALLATION

Advertising