598-1325-00

Keep lamps at least 2" (51 mm) from the

sensor and 2" (51 mm) from combustibles.

Lock Nuts

Mount the Light Control

Place the mounting bolt through the front of the

junction box cover. Push the small gasket hole over
the mounting screw.

Make sure the wire connectors and wires are inside

the junction box. Align the mounting screw with the
center hole in the mounting strap. Secure the fixture
to the mounting strap.

Push the rubber plug firmly into place.

If a wet location junction box was not used, caulk

the wall plate mounting surface with silicone weather
sealant.

Lamp Shade

Set Screw

Bulb Installation

NOTE: When re-lamping, turn power off and let the
fixture cool.

To remove lamp shade, loosen set screw 2 full

turns with a small flat-head screwdriver. Turn shade
counterclockwise and remove.

To remove bulb, pull straight out of fixture.

To replace bulb, push bulb pins into lamp socket.

Check that the bulb is seated properly.

To reinstall lamp shade, place shade on fixture and

align notches on shade with tabs on fixture. Turn
clockwise. Tighten set screw firmly.

Adjust the lamp holders by loosening the lock nuts,

but do not rotate the lamp holders more than 180°
from the factory setting.

Adjust lamp shades by loosening the set screws

several turns, turn shades counterclockwise and
remove. Reinstall the shades in the desired position
and tighten set screws.

Remove the existing light fixture.

Install the mounting strap as shown using two screws

that fit your junction box.

The plastic hanger can be used to hold the fixture

while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.

Route the light control’s wires through the large
gasket holes.

Twist the junction box wires and fixture wires together

as shown. Secure with wire connectors.

White to
White

Black to
Black

Junction box ground wire to
green ground screw on fixture.

Gasket

Mounting

Strap

Mounting

Bolt

Rubber

Plug

Wire the Light Control

WARNING: Turn power off at circuit breaker

or fuse.