Installation – Heath Zenith Motion Sensor Light Control 5408 / 5410 User Manual

Page 2

Advertising
background image

2

598-1303-01

INSTALLATION

For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8
feet (2.4 m) above the ground.

NOTE: If fixture is

mounted higher than 8 ft. (2.4 m), aiming the sen-
sor down will reduce coverage distance.

W

ire

the

L

ight

C

ontroL

For eave mount only:

Wall Mount

Eave Mount

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

Rotate the sensor head towards the clamp screw

joint.

Then rotate the sensor head clockwise 180° so the

controls face down.

Control Switch

Joint Clamp

Black to Black

White to White

Gasket

Drill the holes needed
to mount the backplate
to the junction box.

Remove the existing light fixture.

Route the light control's wires through the large

gasket hole.

Connect the junction box wires to the light control

wires. Twist together and secure with a wire
connector.

If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.

WARNING: Turn power off at circuit breaker

or fuse.

Flash Alert - Activated

(Blue)

NOTICE: 5410 models with Flash Alert feature will
also have a wire loop which can be used to disable
the flash alert feature. This wire loop should not
be connected to any other wire.