Operation, Caution – haier HEATED AIR SPRAY PACKAGE 237410 User Manual

Page 10

Advertising
background image

Operation

12. Adjust the needle valve to set the pump cycle rate

at 1 stroke every 15 seconds.

13. Turn the heater dial to 3. Whenever the heater set-

ting is changed, allow the fluid to circulate and sta-
bilize before checking the temperature (about
minutes) .

A

CAUTION

Be sure the fluid is circulating whenever the heater
is on to reduce the risk of damage to the fluid or

the heater.

14. Follow the fluid manufacturer’s recommendations

for temperature, and adjust the heater accordingly.

If unknown, set the temperature to 110°F (43°C)
at the outlet thermometer. Do not proceed until the

temperature has stabilized. Do not allow the fluid

to exceed

unless your fluid

manufacturer recommends higher

temperatures.

15. Spray fluid into a waste pail for about 10 seconds

to bring heated material to the gun.

16. Hook the drain hose

on the fluid supply pail.

IV.

Setting Fiuid and Air Pressure

.

With the system primed, the gun regulator (6b)
closed, and the pump air regulator (6a) set as
instructed in Step 10 on page 8, adjust the fluid
pressure regulator (44) to the fluid manufacturer’s
specifications, if available. Otherwise, follow Step
2 to determine the fluid pressure setting.

2.

To determine the fluid pressure setting, hold the
gun parallel to the floor. (Be sure to catch the fluid
in a container.) With the gun air pressure turned
OFF, trigger the gun. Adjust the fluid pressure reg-

ulator (4) until the straight fluid stream is within the
range indicated for the viscosity of your fluid before
it drops off. See Fig. 8. Make note of the pressure

on the fluid gauge it is your optimal fluid pressure
setting.

Viscosity

Fluid Droop

Measured with

Zahn cup

Light (18-25 seconds)

(200-250 mm)

Medium (25-40 seconds)

(150-200 mm)

Heavy

seconds)

(100-l 50 mm)

03998

3 .

Be sure the gun’s fan pattern adjusting valve (E)
has been turned OUT fully clockwise and then

turned IN two full turns. See Fig. 9.

4.

Release the trigger. Install the air cap.

5 .

Partially trigger the gun so only air is emitted. Set the
gun air regulator (6b) pressure to 60 psi (4.2 bar)70
psi (4.9 bar).

.

6 .

Spray a stationary test pattern on scrap paper.
Hold the gun 10 to 12 in. (250 to 300 mm) from the
paper, and spray for 2 or 3 seconds. If the spray
pattern is poorly atomized, you may need to adjust
the air or fluid pressure.

If the spray pattern atomization is not fine enough,
increase the gun air pressure. If the spray pattern
atomization is too fine, decrease the gun air pres-
sure. If the atomization is still not good enough, try
lowering the fluid pressure in increments of 2 or 3
psi to achieve the desired finish quality.

NOTE: For the most efficient paint usage, use the
lowest air pressure needed to obtain a good finish.

Higher air pressures create more overspray and

uses more fluid.

7 .

Adjust the fan pattern adjusting valve (E) to fine
tune the spray pattern. Turn counterclockwise
widen spray pattern. Turn clockwise to narrow
spray pattern. See Fig. 9.

308-448

Advertising