Quickspecs – HP ProLiant ML370 G5 User Manual

Page 40

Advertising
background image

3U Rack-Mount Kit

HP StorageWorks USB

HP StorageWorks USB

HP StorageWorks USB

HP StorageWorks USB
Tape Drives, Internal

Tape Drives, Internal

Tape Drives, Internal

Tape Drives, Internal
DAT 40 USB
DAT 72 USB
DAT 160 USB

Internal

USB 2.0 Port on motherboard

N/A

HP StorageWorks USB

HP StorageWorks USB

HP StorageWorks USB

HP StorageWorks USB
Tape Drives, External

Tape Drives, External

Tape Drives, External

Tape Drives, External
DAT 40 USB
DAT 72 USB
DAT 160 USB
1U USB Rack-Mount Kit

External

USB 2.0 Port

N/A

HP StorageWorks SAS

HP StorageWorks SAS

HP StorageWorks SAS

HP StorageWorks SAS
Tape Drives, Internal

Tape Drives, Internal

Tape Drives, Internal

Tape Drives, Internal
LTO-2 Ultrium 448 SAS
LTO-3 Ultrium 920 SAS

Internal

HP SC44Ge Host Bus Adapter

NOTE:

NOTE:

NOTE:

NOTE: Recommended.

416096-B21

HP Smart Array E500 Controller

435129-B21

NOTE:

NOTE:

NOTE:

NOTE: The following SAS Smart Array controllers require ROM
Flash version 2.04 or higher for SAS tape support:

HP Smart Array P400/256MB Controller

405132-B21

HP Smart Array P400/512MB Controller

411064-B21

NOTE:

NOTE:

NOTE:

NOTE: Please visit

http://www.hp.com/go/connect

for details

about minimum SAS controller firmware version and SAS cabling
requirements.

HP StorageWorks SAS

HP StorageWorks SAS

HP StorageWorks SAS

HP StorageWorks SAS
Tape Drives, External

Tape Drives, External

Tape Drives, External

Tape Drives, External
LTO-2 Ultrium 448 SAS
LTO-3 Ultrium 920 SAS
1U Rack-Mount Kit

External

HP SC44Ge Host Bus Adapter

NOTE:

NOTE:

NOTE:

NOTE: Recommended

416096-B21

HP Smart Array E500 Controller

435129-B21

NOTE:

NOTE:

NOTE:

NOTE: The following SAS Smart Array controllers require ROM
Flash version 2.04 or higher for SAS tape support:

HP Smart Array P400/256MB Controller

405132-B21

HP Smart Array P400/512MB Controller

411064-B21

NOTE:

NOTE:

NOTE:

NOTE: Please visit

http://www.hp.com/go/connect

for details

about minimum SAS controller firmware version and SAS cabling
requirements.

HP StorageWorks SCSI

HP StorageWorks SCSI

HP StorageWorks SCSI

HP StorageWorks SCSI
Tape Automation,

Tape Automation,

Tape Automation,

Tape Automation,
External

External

External

External
DAT 72x10 Autoloader
1/8 Tape Autoloader
MSL2024
MSL4048
MSL8096
MSL6000

External

64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2

374654-B21

QuickSpecs

HP ProLiant ML370 Generation 5 (G5)

HP ProLiant ML370 Generation 5 (G5)

HP ProLiant ML370 Generation 5 (G5)

HP ProLiant ML370 Generation 5 (G5)

Storage

DA - 12478 Worldwide — Version 23 — November 14, 2007

Page 40

Advertising