sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.

Altitude

Altitude

Altitude

Altitude

Operating

3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).

Acoustic Noise

Acoustic Noise

Acoustic Noise

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).

Idle

LWAd

6.2 B for Redundant
6.3 B for Non-Redundant

LpAm

43 dBA for Redundant
44 dBA for Non-Redundant

Operating

LWAd

6.2 B for Redundant
6.3 B for Non-Redundant

LpAm

43 dBA for Redundant
44 dBA for Non-Redundant

QuickSpecs

HP ProLiant ML370 Generation 5 (G5)

HP ProLiant ML370 Generation 5 (G5)

HP ProLiant ML370 Generation 5 (G5)

HP ProLiant ML370 Generation 5 (G5)

Technical Specifications

DA - 12478 Worldwide — Version 23 — November 14, 2007