Wire cord connections – haier GDZ22-2 User Manual

Page 23

Advertising
background image

22

1. Remove the screws securing the terminal block access cover

and the strain relief mounting bracket located on the back of the
dryer in the upper corner.

2. Install a strain relief into the power cord entry hole of the
mounting bracket. Finger tighten the nut only at this time.
3. Thread a 30 Amp. Power cord, 245 IEC66(YCW) 450V/750V,
through the strain relief.

4. Attach the power cable earthconductor to the silver
coloured centre terminal on the terminal block. Tighten
the screw securely.

5. Attach the remaining two power cable outer conductors to the

outer silver coloured terminals on the terminal block. Tighten both
screws securely. Warning:Do not make a sharp bend or crimp
wiring/conductor at connections.

6. Reattach the strain relief mounting bracket to the back of the dryer
with two screws. Tighten screws securely.

7. Tighten the screws securing the cable restraint firmly against the
power cable.

8. Tighten the tension relief nut securely so that the tension relief
does not turn.

9. Reinstall the terminal block cover.

Grounding
instruction:

This appliances must be connected to a ground metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or
lead on the appliance.

3-Wire Cord Connections

nut

tighten nut
to these threads

power cord

Strain relief
mounting bracket

G

N

L

Advertising