Testing, Specifications – Heath Zenith DUAL BRITE 598-1041-04 User Manual

Page 4

Advertising
background image

4

598-1041-04

TESTING

Turn on the circuit breaker and light
switch.

The detector is less sensitive to motion directly
towards it and more sensitive to across motion.

Motion

Motion

Least Sensitive

Most Sensitive

OFF 3 6 DUSK TO

HOUR DAWN

TEST 1 5 10 MIN

Set the amount of time after dusk you
want the lights on accent level.

Walk through the coverage area noting
where you are when the lights turn on.

If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity
may cause false triggering in some
installations.

Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 30 ft. (9.1 m) [varies

with surrounding
temperature].

Sensing Angle . . . . . . . Up to 180

°

Electrical Load . . . . . . Up to 100 Watt Maximum

Incandescent

Sensor Capacity . . . . . Up to 360 Watt (3.0 A.)

Maximum

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and

MANUAL MODE

Time Delay . . . . . . . . . 1 , 5, 10 minutes
Dual Brite™ timer . . . . Off, 3, 6 hrs, to dawn

DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at
any time without incurring any obligation to incorporate
new features in products previously sold.

NOTE:

Sensor has a 1

1

/

2

minute warm up

period before it will detect motion.
When first turned on or when
switching modes wait 1

1

/

2

minutes.

TEST 1 5 10 MIN

ON-TIME

OFF 3 6 DUSK TO

HOUR DAWN

Avoid locations that will cause the

control to "see":

• Objects that change temperature rapidly,

such as heating vents and air condition-
ers.
These heat sources could cause false
triggering.

• Areas where pets or traffic may trigger the

control.

Nearby large, light-colored objects

reflecting light may trigger the shut-off feature.
Do not point other lights at the sensor.

9.1 m

Maximum

Maximum

Range

Coverage Angle

1.8 m

180

°

Sensor

Switch the on-time to TEST position and
Dual Brite™ switch to the OFF position.

Advertising