Wiring the power and control cables, Figure 4: connection box – cable routing – Hoffman Media DRIPMASTER EDD-4C User Manual

Page 10

Advertising
background image

10

Wiring the Power and Control Cables

Power and control cables are routed through the bottom of the connection box through two strain
relief bushings.

Power cable entry

Control cable entry

Green ground wire
connects here

Figure 4: Connection box – cable routing

Wire the connection box according to Figure 5. Connections are described in detail in Table 1 on
page 11.

Control

cable

Power

cable

115 VAC

or

24 VAC/VDC

24VAC/DC S.B. - Pre-lube (pump off) mode

LL - Total lack of oil

PULSE - Drip indication

O.K

.

. - Sufficient lubrication

I

I

J

J

J

J

J

J

Voltage selector switch SW1:

115 VAC / 24 V AC/DC

Note: The pump can be optionally
wired to shut down when the O.K.
relay contacts open.

Figure 5: Connection box – electrical terminals: 115 VAC unit shown

1. Set the power switch SW1 located just below the transformer, for line power (115 VAC or

220 VAC) or 24 V AC/DC according to your requirements. See Figure 5.

Advertising