Heath Zenith 5716 User Manual

Replacement sensor head, Operation, Model 5716

Advertising
background image

D

ual

B

rite

®

Replacement
Sensor Head

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Three lamp modes available: Normal, Soft, or Flash.
• Patented D

ual

B

rite

®

Timer.

• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Requirements

• Not for use with fluorescent lights.
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Install sensor in accordance with local codes.

© 2007 HeathCo LLC

598-1307-01

Model 5716

OPERATION

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

D

ual

B

rite

®

Put ON-TIME switch on
the sensor bottom to
TEST and the D

ual

B

rite

®

switch OFF.

D

ual

B

rite

®

TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this
feature. The motion sensing features will continue to work
as described in this manual. If motion is sensed, the light
turns on full bright for the ON-TIME (1, 5, or 20 minutes)
then returns to dim mode.

LAMP MODES

There are three lamp modes (light turn-on effects) avail-
able when motion is detected:

NORMAL - Light instantly comes on.

SOFT - Light starts dim and gradually increases to full
brightness. Light gradually dims to half-bright, pauses,
and then continues dimming to off when motion is no
longer detected and after selected ON-TIME.

FLASH - Light flashes on then off twice before turning
on full brightness.

MANUAL MODE

ON-TIME

TEST

1 5 20

AUTO

Move ON-TIME Switch to 1,

5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the power

off for one minute, then back on. After the calibration
time the control will be in the AUTO mode.

Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

... back on.

1 Second OFF

then...

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 20 min.

x

Manual

Until Dawn*

x

Accent

3, 6 Hr. to Dawn

x

LAMP MODE

NORMAL SOFT FLASH

LAMP MODE

Put the LAMP MODE switch
in the Normal, Soft, or Flash
position.