Installation, Ight, Junction box – Heath Zenith 5716 User Manual

Page 2: Ount

Advertising
background image

2

598-1307-01

ON-TI

ME

RANGE

DU

AL BRITE™

MIN

MA

X

TE

ST

1 5 20

M

INUTES

OFF 3

6 DUSK

TO

H

OUR

DAW

N

LAMP MOD

E

NORMAL

SOFT FLAS

H

W

ire

t

he

l

ight

C

ontrol

These instructions show the sensor wired to floodlamps.
The

white sensor wire is neutral. The black sensor

wire is hot. The red wire is the switched “hot” wire. The
lighting load (300 Watts, 2.5 A max. incandescent only)
is placed across the

white and red wires.

3.

BLACK CONTROL

WIRE &

BLACK

JUNCTION BOX WIRE

1. ALL

WHITE WIRES

2.

RED CONTROL WIRE

&

BLACK LAMP WIRES

Optional: Connect additional
load across the white and red
wires. Total lighting load includ-
ing lampheads on fixture must
not exceed 300W (2.5A).

Junction Box

M

ount

t

he

l

ight

Follow the instructions that came with your light fix-

ture for mounting and adjusting the light fixture.

Keep regular PAR-38 lamps at least 1" (25 mm) from

the sensor. Halogen lamps should be kept at least 2"
(51 mm) from the sensor.

INSTALLATION

For eave mount only:

Swing the sensor head towards the clamp screw

joint.

If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.

Then rotate the sensor head clockwise 180° so the

controls face down.

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
For under eave installation, the sensor head must be
rotated
as shown in the next two steps for proper opera-
tion and to avoid the risk of electrical shock.

Controls

Clamp Screw

Controls

Controls

Remove the existing light fixture, if present.

After screwing the sensor into the wall plate, connect

the junction box wires to the light control wires by twist-
ing together and securing with wire connectors.

WARNING: Turn power off at circuit breaker or

fuse.

Lamp Holders