2d pqa reporting, Full report, Screening report – Hand Held Products IT4800 User Manual

Page 7: 2d pqa reporting -3, Full report -3 screening report -3

Advertising
background image

1 - 3

2D PQA Reporting

Full Report

HHP's 2D PQA reporting can be enabled in two different modes: Full Report or
Screening.

If you are using Quick*View, you can enable Full Report, a listing of all of a sym-
bol's identifying information, measurements, and corresponding grades, by typ-
ing the following menu command:

2D_PQA1

or by scanning the following bar code:

Note: With the IT4600/4800/4X80, the PQA report is sent out as a second data/

beep sequence after the bar code data. The report has its own HHP code
ID of >(0X3E) so it can be uniquely identified.

Screening Report

Screening is a grade-based mode that allows display of a limited list of identify-
ing information, as well as only those measurements that are below Minimum
Acceptable Grade (MAG) level. With the IT4600/4800/4X80, if all of the param-
eters are met in the screening mode, only the bar code data will be output with a
beep. If one or more of the measured parameters fail to meet the MAG, the
PQA message is also sent with a beep.

Note: With the IT4410/4710, screening mode outputs are also accompanied by

a single beep if all parameters are okay or a triple beep if one or more of
the measured parameters fail to meet the MAG.

If you are using Quick*View, you can enable Screening by typing the following
menu commands:

2D_PQA2

when A is the Minimum Acceptable Grade

2D_PQA3

when B is the Minimum Acceptable Grade

2D_PQA4

when C is the Minimum Acceptable Grade

2D_PQA5

when D is the Minimum Acceptable Grade

Full Report

Advertising