Safety Precautions

8

7

Attentions in Installation

In case the power cord of the water heater is
damaged, be sure to have it replaced by after service
technicians with special cord offered by the
manufacturer.

Check if the ameter and the diameter of the wires are in
accordance with the rated current of the water heater. If
necessary please have it checked by experienced
electrician

The water heater adopts power supply of AC 220V~ 50Hz

Be sure to use independent receptacle and earth it reliably.
The receptacle shall comply with the stipulation of
national standard.

The product adopts the patent ¡±

"PTO¢ñ

0" technology of our company. As long as adopting civil power supply, even if

the earthing wire is electrified by mistake, the "PTO¢ñ

0" technology still can block the dangerous electricity, and

ensure your personal safety. But if you find perceptible current, please pull off the power plug and contact our after

service department for maintenance. Do not disassemble by yourself.

Description of the Symbols

Never do that

Be sure to act as per instructions

Set the receptacle of the water heater at dry
position away from water spraying. Do not insert
and pull the power plug with wet hands

In winter of cold area, if the heater is idle for a long
period, please pull the handle of safety valve to discharge
the water. Otherwise it may freeze inside the water heater
and cause damages.

After installation, be sure to fill the heater completely with
water before switching on the power in the first usage.
Children must take bath under the supervision of adult.

In opening and closing the water valve, do not point
the shower head to human body. Otherwise it may
hurt by the spraying hot water.

Safety precaution:

Do not confuse the

water inlet and outlet pipe. The wall bearing the

water heater shall be strong enough to endure a

weight twice as much as that of water heater

filled with water.

If any part is damaged, please contact the local

maintenance agent, and have it replaced with

our spare part.

If the water heater will be installed in the bathroom

without sewer, we suggest you add drain hose.

Fasten the drain hose to the drain thread of safety

valve by twisting (see to Figure 4). Connect the other

end of drain hose to the sewer to avoid polluting the

room by splashing. When the power is switched on,

and the water heater starts operating, there may be

some water discharged from the pressure relief hole

of safety valve. It is due to the water expansion under

heating, and is normal phenomenon. The pressure

relief pipe shall communicate with the air directly. Do

not block it. The discharged water can be led to the

sewer. The drain hose connecting to the safety valve

shall be kept downward sloping in installation and in a

frost-free environment.

Select suitable position on the wall to fix the shower

nozzle bearer. Connect the shower nozzle hose to the

pipeline. Fasten the mixing valve. Check if there's

water leakage at each joint.

Be sure to check and confirm that the tank is filled

with water, there's no leakage at each joint and the

power supply complies with the stipulation before

switching on the power.