NOTICE

Pumping liquids that are not listed may cause damage to the pump.

Agricultural Chemicals

Industrial Chemicals

PUMP PERFORMANCE

The maximum pump discharge capacity is determined when pumping
clear water at 0 ft (0 meters) total head and at sea level. As the total
head (discharge head + suction head) increases, pump discharge
capacity decreases (see figure). If the pump is used at higher
elevations, pump discharge capacity may also decrease. Other
factors affecting pump discharge capacity are:

• The type of chemical being pumped.

• The length and type of the suction and discharge hose used.

Oil Alert

®

System

The Oil Alert system is designed to prevent engine damage caused by
insufficient oil in the crankcase. Before the oil level in the crankcase
can fall below a safe limit, the Oil Alert system will automatically shut
down the engine (the ignition switch will remain in the ON position).

If the engine stops and will not restart, check the oil level (page 8)
before troubleshooting in other areas.

Aatrex

Dual

N-Serve 24

Amiben

Eradicane

Phosphoric Acid
Solutions

Ammonium
Thiosulfate

Extrazine

Poly-N

Banvel

Larsban

Ranger

Basagran

Lasso

Round-up

Bicep

URAN Solutions

Sutan

Bladex

Modown

Treflan

Vernam

Acetic Acid, 20%

Glycerine (Glycerol)

Sodium Acetate

Aluminum Sulfate

Lactic Acid

Sodium Bicarbonate

Ammonium Nitrate

Lead Acetate

Sodium Bisulfate

Ammonium Sulfate

Magnesium Chloride

Sodium Bisulfite

Barium Sulfate

Magnesium Nitrate

Sodium Carbonate,
10%

Borax (Sodium Borate) Magnesium Sulfate

Sodium Chlorate

* Calcium Chloride

Maleic Acid

Sodium Chloride

Citric Acid

Nickel Chloride

Sodium Nitrate

Copper Sulfate

Nickel Sulfate

Sodium Silicate

Detergents (General)

Oleic Acid

Sodium Sulfate

Ethylene Glycol

Phosphoric Acid,
0-80%

Stearic Acid

Fatty Acids

Potassium Carbonate Sulfuric Acid, 0-29%

Ferric Nitrate

Potassium Chloride

Tartaric Acid

Ferric Sulfate

Potassium Nitrate

Vinegar

Ferrous Sulfate

Potassium Sulfate

Water (Clear)

Formaldehyde, 40%

Soaps (neutral)

Water (Salt)

Zinc Sulfate

* Temperature does not exceed 80°F.

The temperature operating range of the pump is between
20 ~ 130°F (-7 ~ 54°C).

Pump Performance (Maximum with clear water)

Total head

105 ft (32 m)

Suction head

26 ft (8 m)

Discharge capacity

220 gal/min (833

/min)

Self-priming time

65 sec at 16.4 ft (5 m)

Pressure

45 psi (310 kPa)

DISCHARGE

HEAD

SUCTION

HEAD

TOTAL

HEAD