L4031A,C POOL HEATER AQUASTAT

®

CONTROLLER

60-2107—5

4

M8815

CLAMP B

CLAMP A

CLAMP SCREWS (2)

BULB
COMPRESSION
FITTING

SEALING
WASHER

BULB

INSERTION LENGTH
APPROX. 3-3/16 in. (81 mm)

SPLIT SLEEVE

Fig. 2. 104486 Bulb compression fitting.

Using Capillary Compression Fitting (Fig. 3)

1. Screw fitting into boiler or pipe tapping.
2. Place packing nut on tubing.
3. Slide bulb completely through fitting.
4. Place composition disk and four slotted brass washers

on tubing in the order shown in Fig. 3. Turn brass
washers so that slots are 180 degrees apart.

5. Slide seal assembly into fitting and tighten packing nut.

COMPOSITION DISK
(SLOTTED)

BOILER PLUG

CAPILLARY TUBING

EXAMPLE OF SLOTTED WASHERS
ASSEMBLED
IN PAIRS:

PACKING NUT

M8816

IMMERSION
BULB

Fig. 3. 104484 Capillary compression fitting.

Using Immersion Well (Fig. 4)

1. Screw the well into the boiler or pipe tapping.
2. Insert the bulb into the well, pushing the tubing until the

bulb bottoms in the well.

3. Attach the retainer clamp to the end of the well spud.

Loosen the draw nut and spread the jaws of the clamp
with a screwdriver if necessary. See Fig. 4.

4. With the retainer clamp attached to a well spud (be

sure jaws of clamp hook over the ridge at the end of the
spud, as shown at point A), adjust tubing to fit through
retainer clamp groove, as shown at point B.

5. Tighten draw nut so retainer clamp is firmly attached to

well spud and tubing is held securely in place.

CAUTION

Do not secure draw nut so tightly that retainer clamp
could collapse tubing

M8777

WELL

BULB

SPUD

MOUNTING
CLAMP

A

DRAW
NUT

TUBING

B

INSERT— MOUNTING CLAMP

SCREWDRIVER

SPREAD JAWS
TO FIT OVER
RIDGE ON SPUD
OF WELL

JAWS

Fig. 4. Immersion well fitting.

Wiring

All wiring must comply with local codes and ordinances.

In all installations, follow the equipment manufacturer
instructions. If not available, use hookups in Figs. 5, and 6.

REVERSE-ACTING
PRESSURE
CONTOLLER

HEATING
SWITCH

PUMP

PUMP
SWITCH

L4031 POOL HEATER
AQUASTAT® CONTROLLER

POOL
CONTROL

HIGH
LIMIT

M4539

PILOTSTAT

GAS VALVE

L1
(HOT)

L2

1

1

2

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

WHEN HIGH LIMIT AND POOL CONTROL ARE CONNECTED IN
SERIES, CURRENT DRAW OF CIRCUIT MUST NOT EXCEED
ELECTRICAL RATING OF POOL CONTROL.

Fig. 5. Typical L4031 connection providing pool

temperature control and high limit protection.