Heath Zenith SH-5511 User Manual

Operation, Compact 150 watt motion sensing halogen, Model sh-5511

Advertising
background image

© 2008 HeathCo LLC

598-1159-06

Model SH-5511

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.

Requirements

• The light control requires 120-volts AC.

Do not con-

nect through a dimmer or other electronic switch.

• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with a junction box

marked for use in wet locations.

• The backplate has knockouts so the sensor can be

mounted on most junction boxes.

• In some applications a universal adaptor plate may

be needed. Adaptors are available at home centers
and electrical supply stores.

Cover

Plate

Light Control

Sensor

3 Wire

Connectors

Gasket

6 Mounting

Screws (3 sizes)

This package includes:

Mounting Strap

Mounting Bolt

Rubber Plug

Plastic Hanger

OPERATION

* resets to Auto Mode at dawn.

TEST

10 5 1

TEST

ON-TIME

Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.

MANUAL MODE

ON-TIME

10 5 1 TEST

... back on.

AUTO

1 Second OFF

then...

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Put the ON-TIME switch in the 1, 5,
or 10 minute position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x

Compact 150 Watt Motion
Sensing Halogen

Halogen

Bulb

Advertising