Bulb Installation and Relamping

When relamping,

turn power off and let the fixture

cool.

Remove the screw that holds the glass cover shut.

Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.

To insert the new bulb, push the bulb into the right

socket so the bulb fits completely into the left
socket.

Check that the bulb is seated properly.

Close the glass cover. Replace screw.

Remove the existing light fixture.

Strip about 5/8" insulation from the existing junction

box wiring.

Route the light control’s wires through the large

hole in the gasket.

Twist the junction box wires and fixture wires together

as shown. Secure with wire connectors.

Mount the Light Control

Align the light control cover plate and cover plate

gasket and the junction box. Insert and tighten the
mounting screws.

If not installed on a weatherproof box or if an adaptor

plate is used,

caulk the wall plate and mounting

surface with silicone weather sealant.

The halogen light must be
mounted horizontally (+/- 4°).

RIGHT

WRONG

Wire the Light Control

White to White

Black to Black

Connect any fixture ground wire(s) and the cover
plate ground screw to the junction box ground
wire.

Gasket

Mounting

Strap

Mounting

Bolt

Rubber

Plug

WARNING: Turn power off at circuit breaker

or fuse.