Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must be

wired through a wall switch.

Some codes require installation by a qualified electrician.
• Switch Module mounts into a standard 4" x 4" junction box.

The SL-5210 package includes:
• The Sensor Module and Switch Module
• Three wire nuts
• Two sensor module screws

© 2003 DESA Specialty Products™

595-4991-06

Motion Sensor
Decorative Lighting
Control

Model SL-5210

OPERATION

10 5 1 TEST

ON-TIME

TEST

* resets to Auto Mode at dawn.

ON-TIME

AUTO

... back on.

1 Second OFF

then...

MANUAL OVERRIDE

10 5 1 TEST

Switch

Module In

Junction Box

Behind Light

Fixture

Sensor Module

Sensor Cord

Existing Light Fixture

Typical Installation

Drip Loop

NOTE: The Drip Loop is neccessary to prevent rain from
running down the cord to the Sensor Module.

Move ON-TIME Switch to

1, 5 or 10 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the power

off for one minute, then back on. After the calibration time
the control will be in the AUTO mode.

Note: When first turned on wait about 1

1

/

2

minutes for the

circuitry to calibrate.

Manual mode only works at night because
daylight returns the sensor to AUTO.

Flip the light switch off for one second then
back on to toggle between AUTO and
MANUAL MODE.

Manual mode works only with the ON-TIME
switch in the 1, 5, or 10 position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 10 min.

x

Manual

Until Dawn*

x

Put the ON-TIME switch on the bottom of
the sensor in the TEST position.

Put the ON-TIME switch in the 1, 5, or 10
minute position.