HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER

68-0244

4

Fig. 3. Typical humidifier installation locations.

IMPORTANT

Mount the humidifier at least 3 in. (76 mm) above
the furnace jacket to allow adequate space for the
solenoid valve and drain line. Check that there is
adequate space above the humidifier to remove and
install the humidifier cover.

2. Tape the template in position and trace around the

template.

3. Remove the template and carefully cut the rectangular

opening.

4. Disassemble the humidifier; remove the cover and take

out the humidifier pad assembly. See Fig. 4.

NOTE:

Sidewalls are interchangeable for either left or
right by-pass installation. To change direction,
remove the screws holding each sidewall,
switch sidewall locations and reinstall the
screws.

5. Position the humidifier housing in the opening (be sure

it is level), so the locking tabs are in place on the lower
sheet metal edge of the opening.

6. Secure the humidifier housing to the opening at the top

and bottom using sheet metal screws.

7. Locate the other plenum and cut an opening for a 6 in.

(152 mm) collar.

8. Install the 6 in. (152 mm) collar.

NOTE:

Be sure to install a duct damper for summer
shutoff on systems with air conditioning.

9. Install a 6 in. (152 mm) diameter duct from the collar to

the humidifier.

NOTE:

Some installations require a 90

°

elbow

attachment to the collar.

10. Seal the duct connections with duct tape.

NOTE:

To avoid sagging and stress on the humidifier,
add support when ducting is longer than
4 ft (120 cm).

11. Reinstall the humidifier pad assembly in the humidifier

housing.

NOTE:

Be sure the water feed tube is not pinched or
kinked.

12. Hinge the cover in place and secure with the

thumbscrew located at the bottom of the cover.

Fig. 4. Humidifier components.

WIRING THE HUMIDIFIER

CAUTION

Hazardous Voltage.
Can cause personal injury or equipment damage.

Disconnect the power supply before installing or
servicing.

On multispeed blower applications, do not wire the
high voltage side of the transformer to the same
power source that services the furnace blower.
Premature transformer burnout may occur.

All wiring must comply with applicable local codes,
ordinances and regulations.

1. Mount the transformer in a convenient location.
2. Connect wires to the 120V side of the transformer.
3. Wire the humidifier solenoid valve, current sensing

relay, or sail switch, humidity control and transformer.
Refer to the humidity control installation instructions for
mounting and wiring information.

NOTE:

Select models of fan centers include humidifier taps
so the current sensing relay or sail switch is not
needed.

M12248C

HORIZONTAL

DOWN

FLO

LOWBOY

HIGHBOY

M14672

WATER
FEED NOZZLE

FRAME

HUMIDIFIER
HOUSING

WATER
FEED TUBE

HUMIDIFIER
PAD ASSEMBLY

COVER

SIDEWALL

BY-PASS SIDEWALL