C. installation of the log set, Ogl-42 installation instructions – Heat & Glo Fireplace OGL-42-NG User Manual

Page 6

Advertising
background image

6

4036-903 Rev C

01/04

OGL-42 INSTALLATION INSTRUCTIONS

1. Gas Line and Valve Assembly Installation

Figure 1 - Placing the Burner Assembly

Note:

Have the gas supply line installed in accordance

with building codes by a qualified installer approved and/or

licensed as required by the locality. In the Commonwealth

of Massachusetts, installation must be performed by a

licensed plumber or gas fitter.

a. Place the burner assembly in the appliance, hand-bend

the flexible stainless steel gas line as shown in Figure 1

and feed the thermocouple line, pilot line and stainless

steel flexible gas line through the hole in the right side of

the appliance. Make sure the excess pilot and

thermocouple line is OUTSIDE the box.

b. The appliance is provided with a stainless steel flexible

connector and a listed (and Commonwealth of

Massachusetts approved) tee-handle manual shutoff

valve.

c. Remove the right side of the valve box for easier

installation of the gas line. Set aside.
1) Bend the flanges of the remaining three sides of

the valve box 90° at the perforations (Figure 2),

place a bead of silicone (not provided) on the back

side of the flanges and slide the valve box into the

square hole on the side of the FPS enclosure. (If

you are not using an FPS enclosure, the valve

must be located in an accessible position where

one person can operate the valve and light the pilot

simultaneously.) All connections within the enclo-

sure need to be accessible for future maintenance

or troubleshooting.

2) Secure the 3-sided valve box to the FPS enclosure

with the drywall screws provided. See Figure 3.

d. Remove the valve from the valve box for ease of assembly

by removing the two screws holding the valve to the valve

bracket.

SAFETY:

This outdoor gas log set must be installed in a UL-listed

outdoor fireplace that has a gas knockout on the right side

with the following minimum firebox dimensions:

Depth: 19 inches

Height: 23 inches

Rear Width: 23 inches

Front Width: 42 inches

Suitable fireplaces would be STS42, OUT42, Montana.

Figure 3 - Secure Valve Box to FPS

Figure 2 - Remove Right Side of Valve Box & Bend Flanges

C. INSTALLATION OF THE LOG SET

Note:

Although knockouts are provided on both sides of the

fireplace, the gas inlet should be routed to the right side of the

fireplace.

Advertising