HP 3000CP User Manual
Page 239
Troubleshooting
Solving Image-Quality Problems
11-15
Problems Due to Misalignment
There are two types of misalignment; vertical and horizontal, refer to page 11-20,
Color Alignment Quality Test for more information.
Misalignment between two primary colors when creating a secondary color can
cause two different effects:
n If there is horizontal misalignment of the colors this will create banding.
n If there is vertical misalignment of the colors, it will create gaps or overlaps
between colors, see
Example C
.
Problem
See:
Corrective Action
1 Black, cyan, magenta and
yellow columns are correct
but banding in any, or all of
the secondary color columns.
This is an indication that there
is a horizontal misalignment.
-
Refer to 11-20, Color Alignment
Quality Test and verify this problem.
See the recommended actions.
Example C