Troubleshooting

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.

Relieve the Pressure before you check or service any
system equipment.

WARNING

Never operate the pump with the warning plate
(20) or the identification plate (40) removed. These
plates protect your fingers from pinching or ampu-
tation by moving parts in the air motor.

NOTE: Check all other possible problems and solu-
tions before disassembling the pump.

Problem

Cause

Solution

Pump fails to operate

Low air supply pressure or restricted air
lines

Increase air supply; clear*

Closed valves

Open

Clogged fluid lines, hoses, valves, etc.

Clear*

Damaged air motor

Service air motor

Empty fluid supply container

Refill and reprime, or flush

Continuous air exhaust

Worn or damaged air motor gasket,
packing, seal, etc.

Service air motor

Erratic pump operation

Empty fluid supply container

Refill and reprime, or flush

Held open or worn intake valve or
piston packings

Clear; service

Pump operates, but output is low
on the up stroke

Held open or worn piston
or packings

Clear; service

Pump operates, but output is low
on the down stroke

Held open or worn intake valve

Clear; service

Pump operates, but output is low
on both strokes

Low air supply pressure or
restricted air lines

Increase air supply; clear*

Closed valves

Open

Empty fluid supply container

Refill and reprime, or flush

Clogged fluid lines, hoses, valves, etc.

Clear*

Packing nut too tight

Loosen

Loose packing nut or worn packings

Tighten; replace

*Follow the Pressure Relief Procedure on page 8. Disconnect the fluid hose. If the pump starts when the air is
turned on again, the hose or gun is clogged.