Wiring CT87N

[1]

If wires will be connected to both R and Rc

terminals, remove the metal jumper.

[2]

Do not connect both O and B if you have a

heat pump. Connect only the O wire. Wrap B

wire with electrical tape and do not use.

[3]

Do not use C, X or B. Wrap bare end of wire

with electrical tape.

Cover plate

(optional)

Thermostat

base

CT87N

Wiring CT87K

2-wire heat-only system: Connect one

wire to R terminal, one wire to W terminal.

3-wire hot water heat-only system: Connect

wires R to R, W to W, and Y to Y terminals.

R

W

Y

CT87K

1. Drill holes at pencil-marked

locations (3/16” for drywall,

7/32” for plaster).

2. Use hammer to tap anchors

into holes until flush with

wall.

3. [Optional] Pull wires through

cover plate (if needed to cover

marks left by the old thermostat).

4. Pull wires through thermostat

base, position over anchors,

then insert mounting screws.

Check level if desired, then

tighten screws.

Mount thermostat base

1. Match each labeled wire with same

letter on the terminal block(s).

2. Use a screwdriver to loosen screw

terminals, insert bare wire into

slots, then tighten screws.

3. Push any excess wire back into the

wall opening.

Labels don't match?

If labels do not match letters on

thermostat, see table below.

Existing wires Connect to:

R RH4 V

Terminal “R

[1]

Rc

Terminal “Rc

[1]

O

Terminal “O

[2]

B

Terminal “B

[2]

GF

Terminal “G

WW1H

Terminal “W

Y Y1M

Terminal “Y

CX B

Do not use

[3]

Connect wires