Operation – Homelite HGCA1400 User Manual

Page 15

Advertising
background image

Page 13 — English

OPERATION

STARTING THE ENGINE

See Figures 4 - 6.

NOTE: If location of generator is not level, the unit may
not start or may shut down during operation.

Unplug all loads from the generator.

Turn the fuel valve to the ON position.

Move the choke lever right to the START position.

NOTE: If engine is warm or the temperature is above
50˚F, move the choke lever left to the RUN position.

Put the engine switch in the ON ( I ) position.

Pull the starter grip and rope until the engine runs (a
maximum of 6 times).

NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.

Allow the engine to run for 30 seconds, then move the
choke lever left to the RUN position.

STOPPING THE ENGINE

See Figures 4 - 5.
To stop the engine under normal operating conditions:

Remove any load from the generator.

Turn the fuel valve to the OFF position.

Put the engine switch in the OFF ( O ) position.

To stop the engine in an emergency situation:

Put the engine switch in the OFF ( O ) position.

USING THE BATTERy CHARGING CABLE

See Figure 7.

CAUTION:

The 12V DC receptacle is designed to charge vented wet
lead acid batteries, not to jump start vehicles. Do not
overcharge battery or leave battery unattended.

Using the battery clamps, connect the charging cable to
the battery terminal. Connect the red wire to the positive
(+) terminal first, then connect the black wire to the nega-
tive (-) terminal. Make sure all connections are secure.

NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.

Connect the battery charging cable to the 12V DC recep-
tacle.

Start the generator.

The battery pack will become slightly warm to the touch
while charging. This is normal and does not indicate a
problem.

NOTE: Only use battery charging cable to charge vented
wet lead acid batteries.

When batteries become fully charged, disconnect the
charging cable from the battery. Disconnect the negative
(black) wire first, then the positive (red) wire, being careful
not to short across the terminals. Always abide by the
safety warnings provided with the battery.

NOTE: Most batteries will be completely charged after
30 to 120 minutes. However, it is highly recommended
that you refer to your battery manufacturer’s instructions
for specific charge times.

Unplug charging cable and store for later use.

Advertising