Trouble

Probable Cause

Correction

1. Blown fuse.
2. Switch is burned out.
3. Connection wire is

loose or damaged.

Note: Any repairs suggested below should be completed by an authorized service
technician.

1. Replace fuse.
2. Replace the Switch.
3. Tighten or replace

the wire.

Motor does not run
at full speed.

1. Power voltage is too low.
2. Motor is damaged.

1. Test voltage.
2. Check and repair motor.

Motor will not reach
full power.

1. Incorrect power wiring.

2. Overload.

1. Have the unit rewired

professionally.

2. Reduce load by clean-

ing filters as necessary.

Motor overheats.

1. Using wrong voltage.

2. Motor is damaged.

1. Verify that the outlet is

115 VAC.

2. Check and repair the

motor.

Insufficient suction
power.

1. Inlet port blocked.
2. 3-Pocket Type Filter is

full.

3. Outlet port blocked.

1. Clean inlet port.
2. Empty 3-Pocket Type

Filter.

3. Clean the outlet port or

adjust the direction of
the outlet.

Unit is shaking.

1. The unit isn’t properly

anchored.

2. The unit isn’t level.
3. Worn or damaged

power cord.

1. Mount the unit firmly.

2. Level the unit.
3. Repair or replace

power cord.

Motor does not run
when power switch
is pressed on.