Optional wiring – Heath Zenith SL-4190 User Manual

Page 3

Advertising
background image

3

595-5628-07

Wiring to Motion Light &

Standard Fixture

BLACK

WHITE

BLACK

(Standard)

When wiring to additional standard
fixture only:
Strip the motion sensor's
red wire and connect to the standard
light's

black wire. Connect all white wires

together. Total fixture ratings must not
exceed 360 Watts (3.0 A.).

NOTE: All wiring between fixtures should

be run in accordance with the National
Electrical Code (Canadian Electrical Code
in Canada) through conduit or another
acceptable means.

Contact a qualified

electrician if there is any question as
to the suitability of the system.

This fixture is provided with a sensor rated

for 360 Watts. Since the fixture is only rated
100 Watts (180 Watts candelabra), 260
Watts (180 Watts candelabra) of additional
load may be controlled by this sensor.

When determining what a fixture is rated

for, do not simply look at the rating on the
lamp in the fixture. Look at the marking
which specifies the maximum lamp watt-
age for which the fixture is suitable.

Once you have selected the fixtures to be

connected and determined their maximum
ratings, add these ratings up. For instance,
if you have 3 fixtures rated 100 Watts, 150
Watts, and 75 Watts respectively, you have
a total load of 325 Watts.

RED

WHITE

BLACK

BLACK

Master

Slave

Wiring to Control One Motion Sensing Lan-

tern (Slave) from Another (Master)

It is also possible to wire two motion sensing coach lights so that either unit will turn on
both lights at the same time (dual master system). It is recommended that only people with
plenty of electrical experience attempt this configuration. Please call our customer service
number (1-800-858-8501) before attempting this wiring.

If the dual master wiring is not

done correctly, it can destroy both motion sensing fixtures and void your warranty.

RED

OPTIONAL WIRING

Advertising