5

595-5628-07

TESTING

Turn on the circuit breaker and light

switch.

The detector is less sensitive to motion
directly towards it and more sensitive to
across motion.

Sensor

Motion

Least Sensitive

Most Sensitive

Walk through the coverage area noting

where you are when the lights turn on.

If you need to change the sensitivity,

temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.

Set the amount of TIME you want the light

to stay on after motion is detected. (1, 5,
or 10 minutes).

Set the amount of time after dusk you want

the lights on accent level.

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 30 ft. (9.1

m ) [ va r i e s w i t h
s u r r o u n d i n g
temperature].

Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . S e e r a t i n g o n

fixture for maximum
wattage.

Sensor Capacity . . . . Up to 360 Watt (3.0

A.) Maximum

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and

MANUAL MODE

Time Delay . . . . . . . . 1, 5, 10 minutes
D

UAL

B

RITE

®

timer . . . . 3, 6 hrs, Dusk-to-

Dawn

DESA Specialty Products™ reserves the
right to discontinue products and to change
specifications at any time without incurring
any obligation to incorporate new features in
products previously sold.

NOTE: Sensor has a 1

1

/

2

minute warm up pe-

riod before it will detect motion. When
first turned on, wait 1

1

/

2

minutes.

TEST 1 5 10 MIN

ON-TIME

OFF 3 6 DUSK TO

HOUR DAWN

Avoid aiming the control at:

• Objects that change temperature rapidly,

such as

heating vents and air condition-

ers. These heat sources could cause false
triggering.

• Areas where

pets or traffic may trigger

the control.

Nearby large, light-colored objects
reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.

30 ft.

(9.1 m)

Maximum Range

Maximum

Coverage Angle

6 ft.

(1.8 m)

180°

Motion

Switch the on-time to TEST position and

D

UAL

B

RITE

®

switch to the OFF position.