C. clearances – Hearth and Home Technologies B-Vent Gas Appliance CB4842MIR User Manual

Page 19

Advertising
background image

Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08

19

0 in.

C

B

A

Note: All pipe clearance
specifications are per vent
manufacturer's installation
instructions.

0 (Clearance to

Standoffs)

30 in.
(762 mm)
clearance to ceiling

1/2 in. (13 mm)

1/2 in.

(13 mm)

Drywall

0 in.

Per Vent
Manufacturer’s
Specifications

Combustible flooring may be installed
next to the front of the appliance.

Combustible Object

36 in.

(914 mm)

Figure 5.2 Clearances to Combustibles

C. Clearances

WARNING! Risk of Fire! Maintain specifi ed air space
clearances to appliance and vent pipe:

• Insulation and other materials must be secured to

prevent accidental contact.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and
making contact with fi replace or chimney.

• Failure to maintain airspace may cause overheating and

a fi re.

Note: If the inside of the framed cavity is to be fi nished,
the framing dimensions must include the fi nished surface.
Example: If drywall is to be attached to the rear wall, the
depth must be measured from the drywall surface.

Note: The appliance must be raised 1 1/4 in. (32 mm) off fl oor so
the Harbor System can be used. Adjust framing and vent locations
accordingly.

NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.

Model

A

Rough Opening

(Width)

B

Rough Opening

(Height)

C

Rough Opening

(Depth)

CB4236MIR

in.

42

38-3/4

23-1/2

mm

1067

984

597

CB4842MIR

in.

48

38-3/4

23-1/2

mm

1219

984

597

Advertising
This manual is related to the following products: