Three Thermostat Wires

If you have three wires for heating only and can operate
the fan using the FAN ON switch, this thermostat works
with your system. However, some hot water (zoned)
heating systems have three thermostat wires. The
thermostat will work only if you install an isolating relay on
these systems. For details, call Honeywell Customer
Assistance Center at 1-800-468-1502.

3

MOUNT WALLPLATE

IMPORTANT

Level for appearance only. The thermostat
functions normally even when not mounted level.

Position the decorator cover plate and wallplate on
the wall. Level the wallplate for appearance if

desired. Use a pencil to mark the two mounting holes that
best fit the application. See Fig. 3.

M12532

DECORATOR
COVER PLATE

WALL

WALLPLATE

PLASTIC SCREW
ANCHOR (2)

CO

OL

OFF

HEAT

F

A

N

O

N

A

U

T

O

Fig. 3. Mounting decorator cover plate and

wallplate to wall.

Remove the decorator cover plate and wallplate
from the wall, and drill two 3/16-inch holes in the wall

(if drywall). For firmer wall material such as plaster or
wood, drill 7/32-inch holes. Gently tap provided anchors
into the drilled holes until flush with the wall.

Reposition the decorator cover plate and wallplate,
pulling wires through the wiring opening. Loosely

insert the mounting screws into the holes.

Level for appearance only; the thermostat functions
properly even when not level. Tighten the mounting

screws.

4

WIRE WALLPLATE TERMINALS

The CT2700 Thermostat is powered through the heating/
cooling system and is adaptable to most 4-wire, 18 to 30
Vac heating-cooling systems. Refer to Figs. 4 through 6 for
some typical system wiring diagrams.

L1
(HOT)

L2

1

1

W

Y

G

R

COOLING
CONTACTOR

FAN
RELAY

HEATING
PRIMARY
CONTROL

24V

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

M12525

T8700

1

1

W

Y

G

R

HEATING
RELAY AND
FAN COIL

24V

POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.

M12543

T8700

L1
(HOT)

L2

1

1

W

Y

G

R

FAN
COIL

COOLING
CONTACTOR
COIL

24V

POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.

M12544

T8700

Fig. 4. CT2700 wiring diagram,

4-wire heat/cool system.

Fig. 5. CT2700 wiring diagram,

2-wire, heat-only system.

Fig. 6. CT2700 wiring diagram,

3-wire, cool-only system.

IMPORTANT

Use 18-gauge maximum wire to wire the
thermostat.