Troubleshooting – Hunter Fan 47350A User Manual

Page 20

Advertising
background image

38

38

TROUBLESHOOTING

Scrambled or Double Display
(numbers over numbers)

No Display

Entire Display Dims

Program Does Not Change at
your Desired Setting

Auto / Fan Does Not turn On

Heating or Cooling Does Not
Go On or Off

Solution

1. Remove clear mylar sticker.

1. Check battery connections and batteries.
2. Press RESET button with a small pin and hold in for two seconds.

1. Replace Batteries.

1. Check that the time is set properly to “AM” or “PM”.
2. Check that the thermostat is not in “HOLD” or “Home Today” modes.
3. Check for the correct day setting.

1. Move HG/HE selector to opposite position

1. Check that the system selector switch is in the correct position

(“HEAT,” “COOL”).

2. There may be as much as a 4 minute delay before the Heat or Cool

system turns On - wait and check. (Compressor protection delay.)

3. Check your circuit breakers and switches to ensure there is power to

the system.

4. Replace batteries.
5. Make sure your furnace blower door is closed properly.
6. If your system only uses 4-wires, be sure the jumper wire is installed

between the RC and RH terminals.

7. Check the position of the Furnace or Heat Pump selector switch: STD - HP.

Problem

41659_model47350A_web.pmd

39

39

Problem (cont.)

Solution (cont.)

Erratic Display

If unit continues to operate in
the Off position

Thermostat permanently reads
“HI,” “LO,” or “ERR-” after
pressing reset button

1. Press the RESET button once with a small pin and hold for two

seconds. The thermostat will need to be re-programmed.

1. Replace unit.

1. Replace unit.

If you experience any other problems, call 1-866-268-1936 from 8 AM to 5 PM Central Time for technical assis-
tance.

Advertising