3. Span setting mode – allows you to adjust

the system ON/OFF cycle rate. The default

setting is 2 (the system cycles ON or OFF

when the temperature is within 1

o

F (0.5

o

C)

above and below the set temperature.) The

span setting can be adjusted if your system is

cycling too fast or too slowly.

Press and hold both the

Up

and

Down

buttons

until the word SPAN appears. Use the

Up

or

Down

button to adjust the span setting.

(Up will increase your cycle time by allowing the system

to run longer; Down will decrease your cycle time by
causing the system to run for a shorter length of time.)

Span settings remain the same for

HEAT

and

COOL

system settings. When batteries are

installed, or the unit is

RESET

, the span cycle

will revert to 2.