Two elbows, Three elbows, Top vent - vertical termination - (continued) – Hearth and Home Technologies 8000TR-OAK User Manual

Page 28

Advertising
background image

Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev. P • 11/08

28

V

1

H

1

Maximum

V

2

V

1

+ V

2

Minimum

One Elbow

3 ft

914 mm

*

*

*

2 ft

607 mm

10 ft

3.1 m

*

*

*

4 ft

1.2 m

20 ft

6.1 m

*

*

*

V

1

+ V

2

+ H

1

= 50 ft (15.2 m) Maximum

*No specifi c restrictions on this value EXCEPT

V

1

+ V

2

+ H

1

cannot exceed 50 ft (15.2 m)

V

1

H

1

+ H

2

V

2

V

1

+ V

2

Minimum

H

1

+ H

2

Maximum

ELBOW ONLY

3 ft

914 mm

*

*

*

3 ft

914 mm

2 ft

610 mm

7 ft

2.1 m

*

*

*

7 ft

2.1 m

4 ft

1.2 m

17 ft

5.2 m

*

*

*

17 ft

5.2 m

H

1

+ H

2

= 17 ft (5.2 m) Maximum

V

1

+ V

2

+ H

1

+ H

2

= 50 ft (15.2 m) Maximum

Figure 7.11

Two Elbows

H

1

V

1

V

2

Three Elbows

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

V

2

Top Vent - Vertical Termination - (continued)

Figure 7.12