Wqa–performance data sheet – Hague Quality Water Intl WATERMAX LC100P User Manual

Page 11

Advertising
background image

WQA–Performance Data Sheet

Reverse Osmosis / Activated Carbon Drinking Water Appliance

General Operation Limits

Model H3500

Model H3000

Membrane Type

TFC

TFC

Production, GPD (LPD)

1

20 (76)

20 (76)

Production, WQA

2

gpd (LPD)

13 (49)

13 (49)

Efficiency Rating

3

17.9%

13%

Recovery Rating

4

21.4% 24%

Pressure, Min-Max, psig

30-100

40-100

Temperature, Min- Max, Deg. F

40°-113°

40°-113°

Chlorine Tolerance, ppm

5

0.0 0.0

Hardness, Max grains

10

10

Iron, Max ppm

<0.1

<0.1

Manganese, Max ppm

<0.05

<0.05

pH, Min / Max

4.0-11.0 4.0-11.0

Hydrogen Sulfide, ppm

0.0

0.0

Turbidity, Max NTU

1.0

1.0

TDS, Max ppm

2000

2000

1

Product output is measured to atmosphere with feed water of 77 degrees F,

60 psig and 360 ppm TDS.

2

WQA production is measured against a pressure tank @ 5 psi backpressure,

77 degrees F, 50 psig and 750 mg/L ± 40 mg/L TDS.

3

Efficiency Rating means the percentage of the influent water to the system

that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage.

4

Recovery Rating means the percentage of the influent water to the

membrane portion of the system that is available to the user as reverse
osmosis treated water when the system is operating without a storage tank
or when the storage tank is bypassed.
NOTE! Actual production rate and TDS reduction will vary depending on
water temperature, water pressure, TDS level, usage and membrane type.

5

Models equipped with TFC membranes incorporate activated carbon as

pretreatment for chlorine.

CAUTION! Contaminants in excess of the established
limits will require pretreatment.

WARNING! Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before and/ or after the appliance.

LIMITED 25 YEAR WARRANTY

25 years—Dispensing spigot, filter housings and caps, PCF housing and cap and membrane housing and cap.
5 years—R.O. storage tank.
2 years—Permeate pump (H3500 only) and automatic shutoff valve.
1 year—Membrane.
Filters—Are not warranted.

REPLACEMENT ELEMENT DIAGRAMS

Routine maintenance is essential for our products to function at peak performance. Estimated costs are listed with the part numbers. We strongly recommend
changing the Sediment Pre-filter, Pre-carbon filter, Post-carbon filter and Prolonged contact filter every six months to one year or sooner depending on the quality
of the feedwater source. Replace the membrane and the drain restrictor when the TDS rejection reaches 75% or less. The practical service life of the membrane is
three years. Contact your local dealer for service and sanitizing for your Reverse Osmosis drinking water appliance.

Appliance

Part Number

Estimated Cost

H3000
Drain Restrictor

200095-24

$6.80

Prolonged Contact Filter

200190

$10.32

R.O. Module

200290

$51.80

Carbon Postfilter

200195

$6.44

Carbon Pre-filter

200195

$6.44

Sediment Pre-filter

P/N 200850

$3.14

Appliance

Part Number

Estimated Cost

H3500
Drain Restrictor

200095-24

$6.80

Prolonged Contact Filter

200190

$10.32

R.O. Module

200290

$51.80

Carbon Postfilter

200195

$6.44

Dual Function Pre-filter

200851

$26.80

WaterMax RO Owner’s Manual

11/11/2009

11