background image

Drawing No. Sheet No. Revision

K6610091

30/43 2005/2/23

(2) DC Power Supply Cable

The DC power cable should be as short as possible to minimize voltage drop.

Table 10.2 Interface cable (WIDE, Single-ended mode)

Cable Type

Maximum cable length

Fast-5

Fast-10

Ultra

(Fast

20)

SCSI interface

Flat Ribbon or

Twisted Pair

6m

(16 units max.)

3m

(16 units max.)

3m (4 units max.) or

1.5m (8 units max.)

DC power supply AWG#20

3m

Table 10.3 Interface cable (WIDE, LVD mode)

Cable

Type

Maximum

cable

length

Ultra2 (Fast-40), Ultra160 (Fast-80) , Ultra320 (Fast-160)

SCSI interface

Flat Ribbon or

Twisted Pair

12m (16 units max.)

DC power supply AWG#20

3m

Shield the cables as necessary to improve the interface noise immunity, especially
if the cables run close to noise generating devices or exit the frame or chassis.