Drawing No. Sheet No. Revision

K6610091

41/43 2005/2/23

12.2.4 Enable Delayed Start

WIDE LVD

No.

Option Jumper Connector (C3)

Meaning

Remove the Jumper Socket
for C3-13,14 (Default)

1

Install the Jumper Socket
for C3-13,14

2

Spindle motor automatically
starts when the power is on.

Spindle motor starts in
sequence via ID number x 10
seconds from the time power is
applied

(NOTE 1)

1

2

13

23

14

24

1

2

13

14

23

24

Note 1. This time is as follows:

ID number 0

to

7 : ID number x 10sec

ID number 8

to

15 : (ID number - 8) x 10sec

Note 2. This jumper is valid only when Auto Start setting is done.
Note 3. If setting for Delayed Start is done by host via SCSI bus connector (C1) in

SCA-2 LVD drive, remove jumper in C3-13,14.

Note 4. If DELAY START in SCSI bus connector (C1) in SCA-2 LVD drive is
grounded by host, jumper setting in C3-13,14 is invalid.