To begin, press and hold the

s

and FAN

buttons until the display changes.

Press

s

or

t

to change settings.

Press NEXT to advance to the next function.

Press DONE to exit and save settings.

Function

number

Setting

1

0

Done

Next

Installer setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling

system, and customize feature operation as desired.

Setup function

Settings & options (factory default in bold)

0

Zone Instance

0

Not Zoned

1–9 Zoned (default setting 2)

1

System type

0

1 heat/1 cool conventional

1

1 heat/1 cool heat pump (no aux. heat)

2

Heat only — 2-wire systems, 3-wire zone valves (Series 20), and nor-

mally open zone valves

3

Heat only with fan

4

Cool only

5

2 heat/1 cool heat pump (with aux. heat)

6

2 heat/2 cool conventional

7

2 heat/1 cool conventional

8

1 heat/2 cool conventional

9

2 heat/2 cool heat pump (no aux. heat)

10

3 heat/2 cool heat pump (with aux. heat)

A

Auto Discover

2

Changeover valve

(O/B terminal)

0

Changeover valve (O/B terminal energized in cooling)

1

Changeover valve (O/B terminal energized in heating)

3

Fan control

(heating)

0

Gas or oil furnace — equipment controls fan in heating

1

Electric furnace — thermostat controls fan in heating

5

Stage 1 heat cycle

rate (CPH: cycles/hour)

5

For gas or oil furnaces of less than 90% efficiency

1

For steam or gravity systems

3

For hot water systems & furnaces of over 90% efficiency

9

For electric furnaces

6

Second Stage Heat

Cycle Rate

5

Standard Gas or Oil Furnace

1

Steam or Gravity

3

90% + Efficient Furnace or Hot Water

9

Electric Furnace

[Other options: 2, 4, 6, 7, 8, 10, 11, 12 for Special Applications]

A

Auto Discover

7

Third Stage Heat

Cycle Rate

5

Standard Gas or Oil Furnace

1

Steam or Gravity

3

90% + Efficient Furnace or Hot Water

9

Electric Furnace

[Other options: 2, 4, 6, 7, 8, 10, 11, 12 for Special Applications]

A

Auto Discover

8

Emergency Heat

Cycle Rate

9

Electric Furnace

[Other options: 1–8, 10, 11, 12 for Special Applications]

A

Auto Discover