Alternate wiring (for heat pumps only)

Leave metal jumper in place, connecting R & Rc

terminals.
If your old thermostat had both V and VR wires,

stop now and contact a qualified contractor for

help.
If your old thermostat had separate O and B

wires, attach the B wire to the C terminal. If

another wire is attached to the C terminal, stop

now and contact a qualified contractor for help.
If your old thermostat had Y1, W1 and W2 wires,

stop now and contact a qualified contractor for

help.

If L terminal is used, C terminal wire must be

connected (contact a contractor if there is no C

wire).
If E and Aux terminals do not each have a wire

connected, use a small piece of wire to connect

them to each other.