OPERATING INSTRUCTIONS

Testing the Battery

Undercharged lead-acid batteries will freeze during cold weather.

WARNING! NEVER TEST OR CHARGE A FROZEN BATTERY.

1.

To help ensure a good connection, clean battery terminals with a solution of

baking soda and water, and wipe the battery terminals with a cloth to remove
any dirt and grease.

2.

Connect the red (positive) Cable Clamp (A) to the positive terminal (+) on the 6

or 12 V lead-acid battery. (See photo above.)

3.

Connect the black (negative) Cable Clamp (B) to the negative terminal (–) on the

battery. Turn clamps slightly to ensure a good connection.

4.

With the clamps connected, the tester’s gauge will show the battery’s current

charge. If it is less than 12 V on a 12 V battery (or 6 V on a 6 V battery),
disconnect the battery and recharge before testing. If recharging will not bring
the reading above the appropriate voltage (noted above), the battery is defective.
If it shows no reading, verify that the tester is connected properly. If the tester
is connected properly, the battery is defective.

5.

Press (and hold) the Toggle Switch (C) for at least 5 seconds to simulate an

actual load on the battery.

6.

View the Meter Display (D) and read the battery condition. Refer to the “Battery

Condition Analysis” section on the next page.

7.

Release the Toggle Switch (C) and remove the Cable Clamps from the battery.