Comfort Control Assembly

Controls and Indicators (figure 5)

Table 2. Control and Indicator Functions

Name

Function

Main Switch

Simple on/off switch. Move to ON for heater to run.



Note: Green light will come on but heater will not start until

heat is called for by the temperature control or remote room
thermostat.

Temperature Control
Knob

Controls the temperature in the heated area by way of an
internal thermostat. Temperature range is 45-95 degrees F.Turn
clockwise to increase. The control has a detent when turned
counter clockwise, which locks out this thermostat. This will not
shut off the heater (see main switch)

Green LED

Indicates when the heater is on and ready to operate.

Red LED

Indicates when a fault has occurred by flashing a code.

Remote Room
Thermostat
(not pictured)

An optional calibrated room thermostat kit P/N 51643 can be
attached for beverage body or cargo heating.

2'/ , 5*

. 46+?  

 46+? +-)-&)

- %-&



Note: When a remote room thermostat and the Comfort Control are used

together, either one will start the heater, after the main switch is ON.