HE360A,B POWERED FLOW-THROUGH HUMIDIFIER

5

68-0194—2

SAIL
SWITCH

HUMIDIFIER

120 VAC

M12685

YELLOW WIRES

1

1

2

2

POWER SUPPLY. PROVIDE DISCONNECT
MEANS AND OVERLOAD PROTECTION
AS REQUIRED.

24V WIRING.

MECHANICAL
HUMIDISTAT

Fig. 8. Typical wiring diagram of sail switch with humidifier.

DEHUM

YELLOW

YELLOW

RED

RED

BLACK

BLACK

DEHUM

HUM

HUM

K1

HOT

COM

OUT

OUT

G

CG

CW

W

24VAC

HUMIDIFIER

CONNECTOR

SOLENOID

FROST FACTOR
SETPOINT DIAL

1

1

2

3

POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.

24V WIRING.

120
VAC

1

2

ELECTRONIC HUMIDISTAT

M12820A

HEAT ONLY APPLICATIOIN SHOWN. SIMILAR WIRING
REQUIRED IN HEAT AND COOL SYSTEM WITH ONE
OR TWO TRANSFORMERS.

ROOM THERMOSTAT

3

L1
(HOT)

L2

1

R

W

G

FAN
RELAY

HEAT
RELAY

FURNACE
TRANSFORMER

Fig. 9. Typical wiring diagram for humidifier using H1008 Automatic Humidity Control.

)RU3HUIHFW&OLPDWH&RPIRUW&HQWHU

&RQWURO

&RQQHFWLRQV

1. Connect only the two yellow wires to the W8900 (red

wire connections are not used). See the typical
wiring diagram in Fig. 10.

For additional mounting and wiring information, refer to the
Perfect Climate Comfort Center

installation instructions.

3OXPELQJ6DGGOH9DOYH

Hot or cold water, either hard or softened, can be used in
the humidifier.

1. Use the self-piercing saddle valve included to tap

into the water supply line at an appropriate location.

CAUTION

Equipment Hazard.
Improper installation can cause equipment
damage.
Do not use any line connected to an air

conditioner.

W8900B

PC8900

1

2

3

4

M12819

HE360
HUMIDIFIER

OPTIONAL
OUTDOOR
AIR SENSOR

1

2

2

2

3

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

OPTIMAL CONTROL ACHIEVED WHEN USING OUTDOOR AIR SENSOR.

YELLOW

YELLOW

RED

RED

120
VAC

1

Fig. 10. Typical wiring diagram for humidifier using

PC8900/W8900.