Hoshizaki RELIABILITY IS A BEAUTIFUL THING DCM-270BAH-OS User Manual

Page 21

Advertising
background image

21

PROBLEM

POSSIBLE CAUSE

REMEDY

[5]

a) Fan Motor

1. Motor winding opened. 1. Replace.

2. Bearing worn out.

2. Replace.

3. Wiring to fan motor.

3. Check for loose connection

or open, and replace.

4. Fan blade bound.

4. Check and replace.

b) Timer

1. Bad contacts (X2 relay). 1. Check for continuity and

replace.

2. X2 relay coil winding

opened.

2. Replace.

3. Loose connections.

3. Tighten.

[6]

a) Water Supply

1. Water failure or

pressure too low.

1. Wait until water is supplied

or adjust the pressure range
within 10-113 PSIG.

2. Shut-off valve closed or

restricted.

2. Open.

b) Water Valve

1. Clogged filter.

1. Clean.

2. Coil winding opened.

2. Replace.

c) Float Switch

1. Contacts fused.

1. Replace.

2. Clogged.

2. Clean.

d) Water Control Relay

1. Bad contacts (terminal

nos. 1 and 5).

1. Check for continuity and

replace.

2. Contacts fused

(terminal nos. 3 and 5).

2. Replace.

e) Bin Control Switch

1. Bad contacts.

1. Check for continuity and

replace.

f) Ice Making Switch

1. "OFF" position.

1. Move to "ON" position.

2. Bad contacts.

2. Check for continuity and

replace.

[7]

a)

1. Contacts fused.

1. Replace.

2. Clogged.

2. Clean.

b) Water Control Relay

1. Contacts fused

(terminal nos. 4 and 6).

1. Replace.

Float Switch

Fan motor will not start.

No water or poor flow.

Ice dispenser will not
stop even if out of
water.

Advertising