Hoshizaki RELIABILITY IS A BEAUTIFUL THING DCM-270BAH-OS User Manual

Page 24

Advertising
background image

24

If you experience problems with the ice or water dispense, use the following charts along
with the wiring diagram (section III, 3) to guide you through your troubleshooting.

The following tables show the proper voltage readings for each operation.

Water Dispensing

Ice Dispensing in Continuous Mode

Ice Dispensing in Portion Controlled Mode

Layout of Portion Control Switch Wiring

(Front of Machine)

Lead 1

Lead 2

Dispense Non-Dispense

K2 PIN 6

(LBU)

to GND

or

NEUTRAL

120 VAC

0 VAC

K5 PIN 4

(W/O)

or

(RED) on

sensor

to K5 PIN 5 (Y)

or

(WH) on

sensor

5 VDC

0 VDC

K5 PIN 4

(W/O)

or

(RED) on

sensor

to K5

PIN

6

(W/BR)

or

(BK) on

sensor

5 VDC

5 VDC

Lead 1

Lead 2 Dispense Non-Dispense

K2 PIN 8

(DBU)

to K4 PIN 2

(LBU)

24 VAC

0 VAC

K5 PIN 7

(RED)

to K5 PIN 9

(BK)

5 VDC

5 VDC

K5 PIN 7

(RED)

to K5 PIN 8

(WH)

5 VDC

0 VDC

The K2 connector supplies voltage to the ice and water dispense motors and solenoids
through pins 4, 6, 8. The K2 connector also has the gear motor protect circuit on pins 1, 2
the flush valve circuit on pins 9, 10 and voltage inputs on pins 3, 5, 7.
The K5 connector is used exclusively for the input and output signals for the optical sensors.

Lead 1

Lead 2

Dispense Non-Dispense

K2 PIN 6

(LBU)

to

GND

or

NEUTRAL

120 VAC

0 VAC

K5 PIN 1

(W/R)

or

(RED) on

sensor

to

K5 PIN 3

(W/BK)

or

(BK) on

sensor

5 VDC

5 VDC

K5 PIN 1

(W/R)

or

(RED) on

sensor

to

K5 PIN 2

(W/BL)

or

(WH) on

sensor

5 VDC

0 VDC

Advertising