USING MOTION SENSOR

WALL SWITCH

MODE SELECTION SWITCH

This switch allows you to selects one of three
modes of operation: OFF, AUTO, or ON.

OFF:

Lights stay off.

AUTO:

Lights automatically come on when mo-

tion is detected and the existing light is below the
set level.

ON:

Lights stay on continuously.

ADJUSTMENTS

Time

The length of time that the lights stay on is
adjustable from 5 seconds to 20 minutes. Use a
small Phillips screw driver to adjust the TIME
control (see Figure 4). Turn control clockwise to
increase the time and counterclockwise to de-
crease the time.

Light Level

You can adjust the sensor’s sensitivity to existing
light. Use a small Phillips screw driver to adjust
the LIGHT control (see Figure 4). By turning the
control fully clockwise, the sensor will turn lights
on even in full daylight. By turning the control
fully counterclockwise, the sensor will only turn
lights on when the existing light is very low.

Adjusting the Photocell

1. When the existing light in the room is at the

level you want the lights to turn on, set the
mode selection switch to the AUTO position.

2. Adjust the TIME control to the 5 second

position (fully counterclockwise).

3. Adjust the LIGHT control to the minimum

dark position (fully counterclockwise).

4. Wait for the lights to turn off.
5. Slightly turn the LIGHT control clockwise.

Wait 2 seconds, then move your hand in
front of the sensor. If lights controlled by the
sensor do not come on, repeat this step until
they do. The light will now come on when
the light level is at or below the present level
and motion is detected.

COMPLETING INSTALLATION

1. Replace control panel cover and attach the

decorative wall plate. In installations where
the Heath

®

/Zenith motion sensor switch is

combined with other switches or outlets on
an expanded box, you will need to purchase
a combination wall plate. Various combina-
tion wall plates are available at home centers
and electrical supply stores.

2. Slide the mode selection switch a couple

times to make sure it moves freely.

SPECIFICATIONS

Electrical Input ............................................................................................................ 120V, 60 Hz.
Fluorescent Load ............................... 30 Watts minimum, Up to 400 Watts Maximum Rapid Start
Motor Load ................................................................................................. Up to 1/8 HP Maximum
Incandescent ...................................................................... Up to 500 Watts Maximum at 120VAC
On-Time ....................................................................... Adjustable approximately 5 sec. to 20 min.
Photocell Sensor ..................................................................... From full daylight to less than 1 FC.
Coverage .............................. up to 15 ft. (4.6 m) at 150

°

, up to 30 ft. (9.1 m) in front of the sensor

T I M E

L I G H T

+

+

5 Sec.

Any Light
Level

20 min.

Dark (low
light level)

Figure 4 - Time and Light Adjustments