Hearth and Home Technologies SMART-BATT-II User Manual

Page 3

Advertising
background image

3

Figure 4. Millivolt with Rocker Switch and Receiver

Figure 5. Millivolt with 3 Wire

If your fireplace is wired like Figure 3 find the leads on back of the switch marked “For use with remote or wall switch only” and
take the leads and plug them into wire lead on remote receiver box (see Figure 4).

3-WIRE ASSEMBLY

PIEZO

RED

WHITE

PILOT

THERMOCOUPLE

VALVE

If your fireplace is wired like Figure 5 remove 3 wires from the valve by unplugging the spade from the valve. Install the jumper
wire on the terminal on the valve as shown in Figure 6. Then install one of the leads from the receiver onto the valve and the
other wire onto the lead from the jumper wire.

B. Wiring Millivolt Valve with 3-Wire Assembly

FEMALE

MALE

MALE

FEMALE

RED

BROWN

VALVE

1

23

REMOTE

RECEIVER

BOX

ON/OFF

REMOTE SWITCH

FOR USE

WITH REMOTE

OR WALL

SWITCH ONL

Y