6 Faults

6.1 Correcting faults

This section describes the steps to be taken in the event that faults with
the unit occur during operation.

1.

Reset control electronics (

Chapter “Resetting the control electronics”,

Page 74

).

2.

Observe the information in the table “Causes of faults and
troubleshooting” (

Chapter “Cause of errors and troubleshooting”,

Page 75

).

3.

Contact customer service.

6.2 Resetting the control electronics

Requirements

Unit is switched on

Errors in the program sequence (e.g. deviations from the set values) can
be corrected by resetting (initialising) the control electronics.

This resets the electronics to the start mode.

NOTICE

Stored programs are not deleted when doing this!

1.

Hold O n / O f f ( 1 ) pressed for about 8 seconds, until the control
electronics switch off.

The multi-function display (4) goes dark.

2.

After about 10 seconds, the control electronics switch on again
automatically.

12. 08. 2008

13:32

Demo mode

Menu

RackCont.

ΔT/LTC/...

3.

If the unit is switched off and O n / O f f ( 1 ) is pressed for longer than
20 seconds, the control electronics change to Demo mode.

The multi-function display (4) shows “Demo mode”.

4.

To leave demo mode, switch off the unit and press O n / O f f ( 1 ) until
the unit switches on again.

12. 08. 2008 13:32

Menu

RackCont.

ΔT/LTC/...

The control electronics switch back to the normal operating mode.

Unit is in start mode (standby).

Global Foodservice Solutions

Operating manual

74

SmartCombi

Faults